Parameter Programming is a means by which the spa owner / user can
change the various timing elements and calibrate temperature. The
process is simple and intuitive. Only 3 keys are used: UP, DOWN and SET.
To program one or more parameters follow the outlined procedure.
- Press SET and DOWN keys together. The first message in the menu,
FP1 will be displayed.
- Use the UP & DOWN keys to scroll thru the messages in the menu.
- Press the SET key to display the current value associated with
the current message.
- Use UP or DOWN keys to increase or decrease the value.
- Press SET to lock in the new value and return to the menu.
- If another item needs programming go to number 2 above.
- To save changes scroll to message SEND and press SET.
- To discard changes ad restore previous values scroll to message
CANC and press SET.
The menu of parameters is circular. Scrolling is from first to last
of from last to first.
When in programming mode please note that this mode will be cancelled
if there is no key activity for a period of 60 consecutive seconds.
Programming mode is aborted and all changes will be restored to previous
values.
PROGRAMMING FILTRATION PERIOD
| Press |
Display |
Explanation |
| SET & UP |
FP1 |
Start programming the display first message is Filtration
period 1 |
| UP |
FP2 |
Scroll up to Filtration Period 2 |
| SET |
12:00 |
Select FP2. The display shows the current FP2 start time
with the hour portion flashing. |
| UP |
1:00 |
Increase the hour value by 1 |
| UP |
5:00 |
Press UP key 4 more times or press and hold for auto repeat. |
| SET |
5:00 |
The hour is set, the minute portion flashes |
| DOWN |
5:45 |
Press UP 15 times or press and hold for auto repeat |
| SET |
FP2 |
FP2 set to 5:45 PM & the current message is displayed again |
| DOWN |
FP1 |
Scroll to previous message. |
| DOWN |
CANC |
Previous message - if you press SET when CANC is displayed
all changes will be discarded. |
| DOWN |
SEND |
Previous - save changes |
| SET |
TEMP |
Changes saved |
| |
|
|
Exit programming mode.
Display current spa temperature, time or Operating message.
PARAMETER MENU LIST
| Msg |
Min |
Def |
Max |
Detail |
| FP1 |
|
12:00 |
|
Start time of filtration period 1 |
| FP2 |
|
12:00 |
|
Start time of filtration period 2 |
| FP3 |
|
12:00 |
|
Start time of filtration period 3 |
| FP4 |
|
12:00 |
|
Start time of filtration period 4 |
| |
|
|
|
|
| |
|
|
|
Note: If filtration periods overlap, the most recent
period (last) is in effect. |
| |
|
|
|
|
| SIL |
|
12:00 |
|
Start time of the silence period. This is a period during
which nothing will run. It overrides all filtrations, the
economy cycle, and temperature sampling. Except if temperature
drops below 40 degrees. A spa may be installed near a bedroom
and need not come on at specific times. |
| FP1d |
0 |
0 |
240 |
Duration in minutes FP1 timer will run. |
| FP2d |
0 |
0 |
240 |
Duration in minutes FP2 timer will run. |
| FP3d |
0 |
0 |
240 |
Duration in minutes FP3 timer will run. |
| FP4d |
0 |
0 |
240 |
Duration in minutes FP4 timer will run. |
| |
|
|
|
|
| SILd |
0 |
0 |
12 |
Duration in hours the Silence Timers runs. Only a user may
override the silence timer |
Note: Keep the valve of any timer to 0 to keep from
running. Filtration timers must be programmed first one first. If the
FP1d (first) timer has a duration of 0, Auto Filtration will be in
effect and all 4 programmed timers will be disabled.
| Msg |
Min |
Def |
Max |
Detail |
| CLDN |
30 |
60 |
180 |
Cool Down cycle in seconds. Whenever the heater is turned
off the pump running the extra seconds to even the temperature
of the heater element and the surrounding water to prevent scale
build up and premature heater failure. |
| ECL |
60 |
180 |
240 |
Economy Cycle Length. Time in minutes to specify the
intervals between spa temperature sampling when the spa is not
in use. During this period the spa is in Economy mode.
Temperature is sampled at the end of the period. Press any key
to cancel this mode. |
| CHCL |
0 |
60 |
180 |
Channel Clear. Time in seconds to clear the air channel and
the secondary pump(s) plumbing if the spa has not been used for
a period of 24 hours. This prevents water stagnation in the
plumbing. |
| UTO |
10 |
20 |
60 |
User Time Out. The time in minutes from starting any device,
after which all devices will be turned off, and the spa put in
"not in use mode." if you should leave the spa with a pump or
light running, it will be turned off after the specified time. |
| PUF |
30 |
120 |
180 |
Post Use Filtration. Time in minutes to perform Post
Use Filtration this is the optimal time to filter the spa. When
you have finished using the spa, that is when it needs
filtration the most. Press the SET key to turn everything off
and start the cycle. This is performed only once and after
pressing the SET key. It is in addition to the standard
filtration cycles. Pressing any other device key will cancel
this function. |
| CALB |
194 |
204 |
218 |
This is not a time element. It is one of the
distinctive features of the SmarTouch Control System. The number
is internal and is indicative of what the processor sees as
temperature reading. Increase this value by 1 to decrease
the displayed temperature by ½ a degree. decrease this number by
1 to increase displayed temperature by ½ a degree. For example
if the controller is displaying a temperature 2 degrees lower
than real temperature, increase the number by 4 to get a correct
reading. The total range of this parameter is 10 degrees
Fahrenheit. Before doing a calibration Please read warnings note
at end of this page. |
| SEND |
|
|
|
This menu message has no numerical value. Pressing SET while
it is displayed records and saves all changes made to all
parameters. |
| CANC |
|
|
|
This menu message also has no value. Pressing SET while it
is displayed discards all changes made to all parameters and
restores last saved or previous values. |
WARNING
The recommend maximum temperature of a spa is 104º F. The
absolute maximum beyond which no person should ever be exposed
to is 108º F. When you calibrate the spa temperature you are
doing so at your own risk. Obtain an accurate medical
thermometer to check against. Please contact
United Spas Manufacturing for proper
procedure or if you do not feel confident. |
|